<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-28 17-21-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
6.2 kHz 5.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 62 kHz 2598 0,0770
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,0 dBr 5,09 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 62 kHz MIN: 13 kHz % above 76 kHz: 0,0770 Acquired: 2025/01/28 17.20.35 Total samples: 2598 Equivalent time: 0:02:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100
FM Scope MAX: 5,9 dBr MIN: 4,0 dBr AVE: 5,09 dBr % above 12,2 dBr: 0,0 Last value: 4,7 dBr (2025/01/28 17.20.34) 17.06 17.08 17.10 17.12 17.14 17.16 17.18 17.20 0 2 4 6 Pm [dBr]